A Multi-device Power
Protection for All. Protect your PC, external storage
drivers and monitor with battery backup. Spread full-time
surge suppression keeps any remaining integrated
peripherals, like modems (SmartLink modems), printers, and
phone systems safe. Multi-device Power Protection for All
Size Plugs.
Most of the LANs and
PCs use the UPS for protection from power failure and data
lost. But that is not good enough, because the UPS can
only provide limited battery output. When power failure
occurs, someone have to shutdown the file server, or there
would be possibility of abnormal power down and operating
system corruption. Our intelligent power monitoring
software detects the status of UPS through communication
port. When power failure occurs, the software sense the
status and broadcast warning messages to users. When
internal timer count to zero, software will close open
files, shutdown the systems and turn off UPS power. If
power recover during the timer count down period, software
will broadcast a power restored message to users and
systems will not be shutdown. During the timer count down
period, if the software goes into a battery low status,
software will inform systems and shutdown the system in
one minute (default)!!
Features/Specifications
Smartlink 2200VA 115V Pro UPS
Retail Box
Size: 425VA, 625VA, 800VA, 1000VA,
1500VA, 2200VA
Fully digitized microprocessor
controlled
Smart RS-232
communication port
Telephone
/ Modem / Fax / Internet surge suppression
SNMP Capability Lightning and Surge Protection
50/60Hz frequency auto sensing
EMI/RFI noise filter
Short
circuit and overload protection cold start (DC power
on)
Advanced battery
management
Energy saving (UPS
sleep mode)
Automatically
charging when UPS off Site wiring fault indicator
Simulated Sine Wave at 100V/110V/115V/
220V/ 230V/240V +/-5%
Frequency
(On battery)
50 or 60 Hz +/-0.5%
Voltage Regulation
(AVR)
AVR automatically increase output voltage 15%
above input voltage if -9% to -25% of nominal.
AVR decrease output voltage 13% below input
voltage if +9% to 25% of nominal
Transfer Time
2/4 milliseconds including detection time
Protection and Filtering
Spike Protection
320 Joules, 2ms
EMI/RFI Filter
10dB at 0.15 MHz, 50dB at 30MHz
Overload Protection
UPS automatic shutdown if overload exceeds
110% of nominal at 60 seconds and 130% at 3
seconds
Unit Input
Fuse for overload & short circuit protection
10 Base-T Cable Port
Network (UTP, RJ-45) compatible jacks
Short Circuit
UPS output cutoff immediately or input circuit
breaker protection
Battery
Type
Sealed, Maintenance-free Lead Acid with 3-6
years typical lifetime
Typical Recharge Time
4 Hours (to 90% of full capacity)
Protection
Automatic self test & discharge protection,
Replace battery indicator
.Back-up
Time
For computer & monitor
55-65 min*
60-70 min*
70-80 min*
85-95 min*
Physical
Weight Kg (lbs)
13 (28.6)
15 (33.0)
15.6 (34.3)
Dimension (mm)
WxDxH
130x382x201
Alarm
Battery Backup
Slow beeping sound (about 0.47Hz)
Battery Low
Rapid beeping sound (about 1.824 Hz)
Overload
Continue beeping sound
Interface
RS232 Interface
Bi-directional communication port
Environment
Ambient Operation
3,500 meters max. elevation, 0-95% humidity
non condensing,
0-48 deg C
Audible Noise
<40dBA (1 meter from surface)
*
Battery backup time will vary depending on load. Please
verify your load requirements in order not to overload
your UPS.